Full-featured multimeter with built-in thermal imager
15 measurement functions including voltage ac and dc, resistance, continuity, capacitance, diode test, Min/Max/Avg, current ac with included iFlex current probe
Assembled in the USA
Three year standard warranty
CAT III 1000 V, CAT IV 600 V measurement category
Designed for durability, built to withstand a 1 m (3 ft) drop, double insulated with raised rubber holster for increased protection
Full-featured multimeter with built-in thermal imager
15 measurement functions including voltage ac and dc, resistance, continuity, capacitance, diode test, Min/Max/Avg, current ac with included iFlex current probe
Assembled in the USA
Three year standard warranty
CAT III 1000 V, CAT IV 600 V measurement category
Designed for durability, built to withstand a 1 m (3 ft) drop, double insulated with raised rubber holster for increased protection
Fluke 279 FC True-rms Thermal Multimeter
Technical Specifications
| Digital Multimeter Parameters | |
| AC Voltage Accuracy | 1.0%+3 (45 Hz to 65 Hz) |
| AC Voltage Range | 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1000 V |
| AC Voltage Resolution | 0.1 mV / 0.001 V / 0.01 V / 0.1 V / 1 V |
| DC Voltage Accuracy | 0.09%+2 |
| DC Voltage Range | 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1000 V |
| DC Voltage Resolution | 0.1 mV / 0.001 V / 0.01 V / 0.1 V / 1 V |
| Resistance | Max. 50 MΩ |
| Resistance Accuracy | 0.5%+2 |
| Frequency | Max. 100 kHz |
| Frequency Accuracy | 0.1%+1 |
| Capacitance Maximum Range | 9.999 μF |
| AC Current Accuracy | 3.0%+5 (45 Hz to 500 Hz) |
| Continuity Test | Yes |
| Diode Test | Yes |
| Min / Max Recording | Yes |
| Data Hold | Yes |
| Infrared Thermal Imager Parameters | |
| Image Resolution | 80 × 60 |
| Image Capture Frequency | 8 Hz |
| Field of View | 36° (W) × 27° (H) |
| Thermal Sensitivity (NETD) | ≤200 mK |
| Infrared Spectral Band | 7.5 μm to 14 μm |
| Temperature Range | -10°C to 200°C (14°F to 392°F) |
| Temperature Accuracy | ±5°C or 5% |
| Emissivity | Fixed at 0.95 |
| Storage Capacity | 100 images |
| File Format | is2 |
| General Specifications | |
| Battery Life | Charging time: 4 hours; Operating time: 10 hours |
| Dimensions | 215.9 × 93.9 × 57.1 mm (8.5 × 3.7 × 2.25 in) |
| Weight | 0.793 kg (1.75 lb) |
Accessories and Replacement Parts

| Item | Description | Fluke Part or Model Number |
| 1 | Battery Door Assembly (includes tilt stand) | 4693466 |
| 2 | Test Lead Set | TL175 |
| 3 | Alligator Clip, Black | AC175 |
| Alligator Clip, Red | ||
| 4 | 279 FC Quick Reference Guide | 4694103 |
| 5 | 279 FC Safety Information | 4717467 |
| 6 | 9-inch Hanger Strap | TPAK80-4-8001 |
| Hanging Clip | TPAK80-2003 | |
| 7 | USB A to USB mini-B Cable | 1671807 |
| 8 | Soft Carry Case | 3087338 |
| 9 | 7.4 V 3000 mAh Rechargeable Lithium-Ion Battery | BP500 |
| 10 | 15 V dc Charger | BC500 |
| 11 | 10 in. iFlex Current Probe | i2500-10 |
| 18 in. iFlex Current Probe | i2500-18 |